1.
Rev. bras. cir. cardiovasc ; 29(3): 330-337, Jul-Sep/2014. tab, graf
Article in English | LILACS, SES-SP | ID: lil-727173

ABSTRACT

Objective: The objective of this paper is to present the results from Spiral Pump clinical trial after design modifications performed at its previous project. This pump applies axial end centrifugal hydraulic effects for blood pumping during cardiopulmonary bypass for patients under cardiac surgery. Methods: This study was performed in 52 patients (51% males), between 20 to 80 (67±14.4) years old weighing 53 to 102 (71.7±12.6) kg, mostly under myocardial revascularization surgery (34.6%) and valvular surgery (32.8%). Besides the routine evaluation of the data observed in these cases, we monitored pump rotational speed, blood flow, cardiopulmonary bypass duration, urine free hemoglobin for blood cell trauma analysis (+ to 4+), lactate desidrogenase (UI/L), fibrinogen level (mg/dL) and platelet count (nº/mm3). Results: Besides maintaining appropriate blood pressure and metabolic parameters it was also observed that the Free Hemoglobin levels remained normal, with a slight increase after 90 minutes of cardiopulmonary bypass. The Lactate Dehydrogenase showed an increase, with medians varying between 550-770 IU/L, whereas the decrease in Fibrinogen showed medians of 130-100 mg/dl. The number of platelets showed a slight decrease with the medians ranging from 240,000 to 200,000/mm3. No difficulty was observed during perfusion terminations, nor were there any immediate deaths, and all patients except one, were discharged in good condition. CONCLUSION: The Spiral Pump, as blood propeller during cardiopulmonary bypass, demonstrated to be reliable and safe, comprising in a good option as original and national product for this kind of application. .


Objetivos: Apresentar resultados da aplicação da bomba espiral que emprega efeitos hidráulicos centrífugo e axial de bombeamento como elemento propulsor do circuito de circulação extracorpórea em pacientes submetidos a cirurgias cardíacas após modificações introduzidas no design do projeto original. Métodos: O estudo foi realizado em 52 pacientes (51% masculinos), com idade entre 20 a 80 (67±14,4) anos, peso 53 a 102 (71,7±12,6) kg, submetidos na maioria a cirurgia de revascularização miocárdica (34,6%) e Orovalvar (32,8%). Além das avaliações rotineiras, foram registrados rotação, tempo de CEC e para análise do impacto traumático à crase sanguínea, hemoglobina livre na urina (+ a 4+), desidrogenase láctica, fibrinogênio (mg/dL) e contagem de plaquetas (nº/mm3). Resultados: Observou-se a manutenção de parâmetros pressóricos e metabólicos adequados. Quanto aos marcadores de danos à crase sanguínea, as alterações estiveram proporcionais ao tempo maior de circulação extracorpórea. Os níveis de Hemoglobina Livre permaneceram com valores normais, com ligeiro aumento a partir dos 90 minutos de circulação extracorpórea. A Desidrogenase Láctica mostrou aumento, variando as medianas entre 550 a 770 UI/L enquanto o Fibrinogênio mostrou queda das medianas de 130 a 100 mg/dl. O número de plaquetas mostrou ligeira queda das medianas variando entre 240.000 a 200.000/mm3. Não ocorreram dificuldades de saída de perfusão, não se observou óbito imediato e todos os pacientes, exceto 1, obtiveram alta hospitalar. Conclusão: A bomba espiral aplicada como bomba propulsora de sangue durante cirurgia cardíaca se mostrou confiável e segura, não causou impacto traumático ...


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged , Aged, 80 and over , Young Adult , Cardiac Surgical Procedures/instrumentation , Cardiopulmonary Bypass/instrumentation , Heart-Assist Devices/standards , Cardiac Surgical Procedures/methods , Cardiopulmonary Bypass/methods , Equipment Design/standards , Equipment Safety , Fibrinogen/analysis , L-Lactate Dehydrogenase/blood , Medical Illustration , Models, Cardiovascular , Platelet Count , Reproducibility of Results , Statistics, Nonparametric , Time Factors , Treatment Outcome
2.
Rev. bras. eng. biomed ; 25(2): 101-105, ago. 2009. ilus, tab
Article in Portuguese | LILACS | ID: lil-556120

ABSTRACT

Técnicas cirúrgicas, próteses e dispositivos implantáveis utilizados pela cardiologia estão em constante desenvolvimento. Alguns institutos de pesquisas e universidades desenvolvem simuladores hidrodinâmicos com capacidade de reproduzir os níveis de pressão e vazão do sistema cardiovascular humano, com pistões, válvulas, câmaras de complacência, dispositivos para ajustes e medição de pressão e vazão. Este artigo apresenta o desenvolvimento e a avaliação de um fluxômetro eletromagnético (FE). O custo elevado de um fluxômetro por ultrassom (FUS) pode inviabilizar algumas pesquisas com simuladores; desta forma, uma alternativa com menor custo é apresentada neste trabalho. Baseado na indução eletromagnética para medição de vazão em um fluido iônico, o FE desenvolvido mostrou ser uma solução de baixo custo. O transdutor foi montado em um tubo de plástico com diâmetro interno de 9,5 mm, excitado por um campo magnético de 0,35 T, possui 4 eletrodos que, ligados a um circuito eletrônico, fornecem tensão elétrica proporcional à velocidade do fluido. A equação da tensão induzida, técnicas para calibração, ensaios e resultados são apresentados. Para a realização dos ensaios, foram utilizados um simulador cardiovascular e um FUS como referência. Os dados foram obtidos por hardware e software da National Instruments. Dentre os resultados, destaca-se o baixo desvio padrão de 0,043 L/min do FE para uma vazão de 3,56 L/min. O maior erro porcentual relativo foi de 1,49 ± 1,25%. Em um dos gráficos de vazão do FE observou-se um comportamento não monotônico, confirmado por uma análise da resposta em freqüência, observando-se maior amplitude na segunda, terceira e quarta harmônicas. Os resultados indicaram que o FE pode substituir o FUS em aplicações com simuladores hidrodinâmicos.


Implantable devices, prosthesis and their associated surgical techniques in cardiology are constantly under development. Many research groups have been using hydrodynamic simulators as a tool to assist the development in cardiovascular area, capable to mimic pressure and flow found in human cardiovascular system. They are made with plastic tubes, compliances chambers, valves, moving diaphragms and clamps for pressure and flow adjustments. The high cost of ultrasonic flow meters (UF) may difficult, for some research groups, the development of their own mock systems. This paper presents a simple and low cost electromagnetic flow meter (EF) useful for those cardiovascular simulation systems. EF measures flow of ionic fluids based on electromagnetic induction. A special transducer was assembled directly on a plastic tube with 9.5 mm of inner diameter. The transducer has 4 electrodes and, when excited by a magnetic field of 0.35 tesla, detects electric tension that is proportional to the fluid velocity. In this paper, induced electric potential equation, calibration techniques, performance tests and results are presented. A cardiovascular simulation system was used as test setup with an UF (Transonic Systems Inc.) as comparative flow meter. The signals were acquired by a PCI-6036E card and processed with LabView® 7.1 (National Instruments). The results from EF showed a standard deviation (SD) of 0.043 L/min for a flow of 3.56 L/min. The largest relative error was of 1.49 ± 1.25%. In one flow signal from the EF, the non monotonic behavior suggests a rich harmonic signal, which was confirmed by an analysis in the frequency domain. In vitro performance tests indicated that our EF can substitute the commercial available UF for hydrodynamic simulator application.


Subject(s)
Flow Measurements , Flowmeters , Models, Cardiovascular , Computer Simulation , Risk Measurement Equipment , Diagnostic Techniques, Cardiovascular/instrumentation
3.
Rev. bras. cir. cardiovasc ; 22(2): 224-234, abr.-jun. 2007. ilus, tab, graf
Article in Portuguese | LILACS, SES-SP | ID: lil-461764

ABSTRACT

INTRODUÇÃO: O trabalho aborda projeto original relativo à concepção, ao desenvolvimento e à aplicação clínica de bomba sangüínea que associa forças centrífuga e axial de propulsão hidráulica, baseada no princípio de Arquimedes, denominada Bomba Espiral (BE), tendo recebido Patente Nacional e Relatório Preliminar Internacional categorizando-a como invento. MÉTODO: Visa avaliar sua capacidade hidrodinâmica e seu impacto aos elementos figurados do sangue por meio de testes "in vitro", como Eficiência Hidrodinâmica, Hemólise Normalizada e Visibilização de Escoamento, e, nos testes "in vivo" experimentais, feitos em carneiros submetidos a Circulação Extracorpórea (CEC), e clínico, em 43 pacientes submetidos a operações cardíacas com CEC, nas quais o elemento propulsor foi a BE. RESULTADOS: Na dependência da distância entre o rotor e a carcaça (fenda) da bomba pôde-se observar que com 1,5 mm gerou escoamento ao redor de 9 L/min, pressão acima de 400mmHg com 1500 rotações por minuto (rpm), índices de Hemólise Normalizada não superiores a 0,0375 g/100l em condições de alto fluxo e pressão, e pelo estudo de Visibilização do Escoamento no interior da bomba não se detectou áreas de estagnação ou turbulência na entrada, saída e junto à extremidade dos fusos. Nas pesquisas "in vivo" experimentais em ovinos em CEC por 6 horas a BE foi capaz de manter parâmetros pressóricos adequados e Hemoglobina Livre entre 16,36 mg por cento e 44,90 mg por cento. Durante sua aplicação em cirurgias cardíacas com CEC, num grupo de 43 pacientes, pôde-se constatar variações pré e pós-CEC, na Hemoglobina Livre de 9,34 a 44,16 mg por cento, no Fibrinogênio, de 236,65 a 547,26 mg por cento, na contagem do número de Plaquetas de 152,465 a 98,139, Desidrogenase Láctica, de 238,12 a 547,26 mg por cento, com tempo de coagulação ativada ao redor de 800 seg. quando em CEC. CONCLUSÕES: A BE mostrou resolutividade por gerar escoamento e pressão adequados, sem causar danos excessivos...


INTRODUCTION: This paper addresses an original project that encompasses the conception, development and clinical application of a helical bypass pump called the Spiral Pump, that uses the association of centrifugal and axial propulsion forces based de the Archimedes principle. This project has obtained a Brazilian Patent and an International Preliminary Report, defining it as an invention. METHODS: The aim of this work was to evaluate the hemodynamic capacity and the impact of its application on blood cells by means of experimental in vitro tests, including hydrodynamic efficiency, effect on hemolysis and flow visualization. Moreover, in vivo experimental tests were carried out on lambs that were submitted to cardiopulmonary bypass for six hours and in 43 patients submitted to heart bypass surgery using the Spiral Pump. RESULTS: When the rotor-plastic casing gap was 1.5mm, the flow generated was nearly 9 L/min, the pressure was greater than 400 mmHg at 1500 rpm, and the normalized hemolytic indexes were not greater than 0.0375 g/100L in high-flow and pressure conditions. Additionally, by the flow visualization techniques, stagnation was not seen inside the pump nor was turbulence identified at the entrance or exit of the pump, or at the ends of the spindles. In the in vivo tests using cardiopulmonary bypasses for 6 hours in lambs, the pump maintained adequate pressure rates and the free hemoglobin levels ranged between 16.36 mg percent and 44.90 mg percent. Evaluating the results of the 43 patients who used this pump in heart bypass operations we observed that the free hemoglobin ranged from 9.34 mg percent before to 44.16 mg percent after surgery, the serum fibrinogen was from 236.65 mg percent to 547.26mg percent, platelet blood count from 152,465 to 98,139 and the lactic dehydrogenase from 238.12mg percent to 547.26mg percent. The Activated Coagulation Time was close to 800 seconds during the bypass. CONCLUSION: The Spiral Pump was...


Subject(s)
Humans , Animals , Guinea Pigs , Heart-Assist Devices/classification , Cardiovascular Diseases/therapy , Hemolysis , In Vitro Techniques , Animal Experimentation , Human Experimentation , Hydrodynamics , Flow Mechanics